<ul id="yaegq"></ul>
  • <tfoot id="yaegq"></tfoot>
    <tfoot id="yaegq"></tfoot>
  • <tfoot id="yaegq"></tfoot>
  • <strike id="yaegq"></strike>
    <ul id="yaegq"><sup id="yaegq"></sup></ul>
    <strike id="yaegq"><rt id="yaegq"></rt></strike>
    <li id="yaegq"><abbr id="yaegq"></abbr></li>
    <ul id="yaegq"></ul>
    歡迎來到上海宸喬生物科技有限公司網站!
    咨詢熱線

    18801803238

    當前位置:首頁   >  產品中心  >  Ultrasep ES液相色譜柱  >  Ion Exchangers(離子交換)  >  Anion Exchanger RP NN (Rapid Determination of Nitr

    Anion Exchanger RP NN (Rapid Determination of Nitr

    簡要描述:These anion exchangers are so called ?permanently loaded“ ion exchangers. They exhibit the excellent performance of silicas and the good stability of RP-phases, which leads to low costs.

    • 產品型號:
    • 廠商性質:生產廠家
    • 更新時間:2024-08-07
    • 訪  問  量:1713

    詳細介紹

     

    Anion Exchangers

     

    UltraSep ES SAX W (Anorganic ions according to DIN 38405)

      

    These anion exchangers are so called „permanently loaded“ ion exchangers. They exhibit the excellent performance of silicas and the good stability of RP-phases, which leads to low costs.

    Stability of UltraSep ES SAXW with phthalic acid/TRIS buffer (1.25/2.5 mM) at pH 6.4

      

    Permanently loaded ion exchangers are not only useful to separate inorganic ions (see Application ANION1) but also to separate natural products with aqueous buffers (nucleotides). They cannot be used with organic-aqueous eluents

    Our permanently loaded ion exchangers are easily to regenerate. For this, we offer a special solution or a regeneration in our firm. 

    If there is a need to chromatograph aqueous solutions highly contaminated with organic material, we recommend to use additionally a RP precolumn (length 33 mm) in front of the precolumn cartridge ( ANION2 Tap water from Berlin).

    By lowering of the strength of the eluent, phosphate appears between nitrite and bromide without the necessity to increase the pH noticeably  In this way, there are good conditions for the conductivity detection too. Furthermore, fluoride is well separated from the injection peak (see Application ANION3).

        
     

    UltraSep ES SAX W Quick Columns

      

    See Applications ANION5 and ANION6

     

    UltraSep ES SAX W33 (Determination of ascorbic acid)

      

    See Applications ANION9

     

    UltraSep ES SAX NN (Rapid determination of nitrite, nitrate, and bromide in drinking water and foodstuffs)

      

    By this exchanger concentrations of nitrite and nitrate can be determined considerably faster and more sensitive than with customary methods. Nitrate, which can be determined by the photometric method only relatively insensitively, is determined by chromatography at 220 nm without previous enrichment to 0.1 mg/l. Bromide is determined at 210 nm with high sensitivity.

    Iodide can be determined also directly at 225 nm. For a quick determination of iodide you can use a column of  UltraSep ES SAX NN with a length of 33 mm.

    The selectivity and rapidity of the determination (phosphoric acid as eluent) can be changFor columns with endcapped packings an additional charge of 10.00 € is calculated.  ed by the pH value (at best pH 3 – 5). Furthermore,  the velocity of elution can also be varied by the concentration of phosphoric acid (at best 10 – 30 mM; see Application ANION4).

       
     

    UltraSep ES RP NN (Determination of nitrite, nitrate, bromate and bromide in drinking water and foodstuffs)

      See Applications ANION7 and ANION8

     

     

    Examples of Analyzed Compounds

    Analyzed in Application
    (AN = ANION)

    Go to

     

    Ascorbic acid

    AN9

    ANION1

     

    Bromate

    AN7, AN8

    ANION2
     

    Bromide

    AN1, AN3, AN4, AN5, AN6, AN7

    ANION3

     

    Carbonate

    AN2

    ANION4

     

    Chloride

    AN1, AN2, AN3, AN5, AN6

    ANION5

     

    Fluoride

    AN3

    ANION6

     

    Nitrate

    AN1, AN3, AN4, AN5, AN6, A7

    ANION7

     

    Nitrite

    AN1, AN3, AN4, AN5, AN6, A7

    ANION8

     

    Phosphate

    AN3, AN6

    ANION9

     

    Sulfate

    AN1, AN2, AN3, AN5, AN6

     

     

     

     

     

     

     

     

     

     

    COLUMNS and  PRICES  ()
     Column size (mm)
    150 x 3125 x 360 x 333 x 3
    UltraSep ES SAX W 270.00  
    UltraSep ES SAX W Guard column RP 18 *   125.00
    UltraSep ES SAX W QC  255.00250.00
    UltraSep ES SAX QCM 270.00  
    UltraSep ES SAX NN  265.00245.00
    UltraSep ES RP NN240,00240,00  
    UltraSep ES SAX W33 295,00  
    * Recommended as precolumn for samples with high content of organic substances.

     

    Size (mm)

     
      10 x 35 x 3 ***  
    Precolumn cartridges
    (Price per pack = 5 pieces)
     170.00170.00
    Activator for ES SAX W (1 ml)12.00  
    Regeneration solution (30 ml) for regeneration by customer33.00  
    *** Only for UltraSep ES SAX W QC.

    產品咨詢

    留言框

    • 產品:

    • 您的單位:

    • 您的姓名:

    • 聯系電話:

    • 常用郵箱:

    • 省份:

    • 詳細地址:

    • 補充說明:

    • 驗證碼:

      請輸入計算結果(填寫阿拉伯數字),如:三加四=7

    聯系我們

    上海宸喬生物科技有限公司 公司地址:上海市阿克蘇路1187號516室   技術支持:化工儀器網
    • 聯系人:王經理
    • QQ:3004300903
    • 公司傳真:021-59100893-802
    • 郵箱:sales@keyanwang.com.cn

    掃一掃 更多精彩

    微信公眾號

    網站二維碼

    主站蜘蛛池模板: 亚洲国产成人久久一区二区三区| 亚洲色成人WWW永久网站| 国产成人综合亚洲一区| 国产成人yy精品1024在线| 四虎成人精品无码| 欧美色成人综合| 天天成人综合网| 久久精品成人一区二区三区| 欧美成人精品第一区| 国产成人精品无码一区二区 | 成人综合婷婷国产精品久久蜜臀| 成人区人妻精品一区二区不卡网站| 国产成人av一区二区三区在线| 久久成人国产精品免费软件| 成人毛片在线视频| 四虎成人免费大片在线| 日韩国产欧美成人一区二区影院| 国产成人啪精品视频免费网| 欧美成人国产精品高潮| 亚洲成人www| 国产成人精品永久免费视频| 欧美成人鲁丝片在线观看| 亚洲欧美一区二区成人片| 国产成人综合久久久久久| 日韩成人精品日本亚洲| 亚洲国产成人精品无码区在线秒播| 成人在线视频免费| 成人看的午夜免费毛片| 一级毛片成人免费看免费不卡| 亚洲国产精品成人综合色在线婷婷| 成人在线视频一区| 成人毛片免费视频播放| 37pao成人国产永久免费视频| 国产v片成人影院在线观看| 国产成人免费在线观看| 成人午夜大片免费7777| 成人免费网站在线观看| 成人国产午夜在线视频| 成人国产一区二区三区| 国产成人精品一区二区三区无码| 成人午夜视频在线播放|