<ul id="yaegq"></ul>
  • <tfoot id="yaegq"></tfoot>
    <tfoot id="yaegq"></tfoot>
  • <tfoot id="yaegq"></tfoot>
  • <strike id="yaegq"></strike>
    <ul id="yaegq"><sup id="yaegq"></sup></ul>
    <strike id="yaegq"><rt id="yaegq"></rt></strike>
    <li id="yaegq"><abbr id="yaegq"></abbr></li>
    <ul id="yaegq"></ul>
    歡迎來到上海宸喬生物科技有限公司網(wǎng)站!
    咨詢熱線

    18801803238

    當前位置:首頁   >  產(chǎn)品中心  >  Ultrasep ES液相色譜柱  >  Ion Exchangers(離子交換)  >  Anion Exchanger SAX W Quick Columns

    Anion Exchanger SAX W Quick Columns

    簡要描述:These anion exchangers are so called ?permanently loaded“ ion exchangers. They exhibit the excellent performance of silicas and the good stability of RP-phases, which leads to low costs.

    • 產(chǎn)品型號:
    • 廠商性質:生產(chǎn)廠家
    • 更新時間:2024-08-07
    • 訪  問  量:1666

    詳細介紹

    Anion Exchangers

     

    UltraSep ES SAX W (Anorganic ions according to DIN 38405)

      

    These anion exchangers are so called „permanently loaded“ ion exchangers. They exhibit the excellent performance of silicas and the good stability of RP-phases, which leads to low costs.

    Stability of UltraSep ES SAXW with phthalic acid/TRIS buffer (1.25/2.5 mM) at pH 6.4

      

    Permanently loaded ion exchangers are not only useful to separate inorganic ions (see Application ANION1) but also to separate natural products with aqueous buffers (nucleotides). They cannot be used with organic-aqueous eluents

    Our permanently loaded ion exchangers are easily to regenerate. For this, we offer a special solution or a regeneration in our firm. 

    If there is a need to chromatograph aqueous solutions highly contaminated with organic material, we recommend to use additionally a RP precolumn (length 33 mm) in front of the precolumn cartridge ( ANION2 Tap water from Berlin).

    By lowering of the strength of the eluent, phosphate appears between nitrite and bromide without the necessity to increase the pH noticeably  In this way, there are good conditions for the conductivity detection too. Furthermore, fluoride is well separated from the injection peak (see Application ANION3).

        
     

    UltraSep ES SAX W Quick Columns

      

    See Applications ANION5 and ANION6

     

    UltraSep ES SAX W33 (Determination of ascorbic acid)

      

    See Applications ANION9

     

    UltraSep ES SAX NN (Rapid determination of nitrite, nitrate, and bromide in drinking water and foodstuffs)

      

    By this exchanger concentrations of nitrite and nitrate can be determined considerably faster and more sensitive than with customary methods. Nitrate, which can be determined by the photometric method only relatively insensitively, is determined by chromatography at 220 nm without previous enrichment to 0.1 mg/l. Bromide is determined at 210 nm with high sensitivity.

    Iodide can be determined also directly at 225 nm. For a quick determination of iodide you can use a column of  UltraSep ES SAX NN with a length of 33 mm.

    The selectivity and rapidity of the determination (phosphoric acid as eluent) can be changFor columns with endcapped packings an additional charge of 10.00 € is calculated.  ed by the pH value (at best pH 3 – 5). Furthermore,  the velocity of elution can also be varied by the concentration of phosphoric acid (at best 10 – 30 mM; see Application ANION4).

       
     

    UltraSep ES RP NN (Determination of nitrite, nitrate, bromate and bromide in drinking water and foodstuffs)

      See Applications ANION7 and ANION8

     

     

    Examples of Analyzed Compounds

    Analyzed in Application
    (AN = ANION)

    Go to

     

    Ascorbic acid

    AN9

    ANION1

     

    Bromate

    AN7, AN8

    ANION2
     

    Bromide

    AN1, AN3, AN4, AN5, AN6, AN7

    ANION3

     

    Carbonate

    AN2

    ANION4

     

    Chloride

    AN1, AN2, AN3, AN5, AN6

    ANION5

     

    Fluoride

    AN3

    ANION6

     

    Nitrate

    AN1, AN3, AN4, AN5, AN6, A7

    ANION7

     

    Nitrite

    AN1, AN3, AN4, AN5, AN6, A7

    ANION8

     

    Phosphate

    AN3, AN6

    ANION9

     

    Sulfate

    AN1, AN2, AN3, AN5, AN6

     

     

     

     

     

     

     

     

     

     

    COLUMNS and  PRICES  ()
     Column size (mm)
    150 x 3125 x 360 x 333 x 3
    UltraSep ES SAX W 270.00  
    UltraSep ES SAX W Guard column RP 18 *   125.00
    UltraSep ES SAX W QC  255.00250.00
    UltraSep ES SAX QCM 270.00  
    UltraSep ES SAX NN  265.00245.00
    UltraSep ES RP NN240,00240,00  
    UltraSep ES SAX W33 295,00  
    * Recommended as precolumn for samples with high content of organic substances.

     

    Size (mm)

     
      10 x 35 x 3 ***  
    Precolumn cartridges
    (Price per pack = 5 pieces)
     170.00170.00
    Activator for ES SAX W (1 ml)12.00  
    Regeneration solution (30 ml) for regeneration by customer33.00  
    *** Only for UltraSep ES SAX W QC.

    產(chǎn)品咨詢

    留言框

    • 產(chǎn)品:

    • 您的單位:

    • 您的姓名:

    • 聯(lián)系電話:

    • 常用郵箱:

    • 省份:

    • 詳細地址:

    • 補充說明:

    • 驗證碼:

      請輸入計算結果(填寫阿拉伯數(shù)字),如:三加四=7

    聯(lián)系我們

    上海宸喬生物科技有限公司 公司地址:上海市阿克蘇路1187號516室   技術支持:化工儀器網(wǎng)
    • 聯(lián)系人:王經(jīng)理
    • QQ:3004300903
    • 公司傳真:021-59100893-802
    • 郵箱:sales@keyanwang.com.cn

    掃一掃 更多精彩

    微信公眾號

    網(wǎng)站二維碼

    主站蜘蛛池模板: 成人看片黄在线观看| 成人av鲁丝片一区二区免费| 成人无码午夜在线观看| 精品成人AV一区二区三区| 亚洲av无码精品国产成人| 中文成人无字幕乱码精品区| 成人深夜福利视频| 国产日韩欧美成人| 免看**毛片一片成人不卡| 麻豆成人精品国产免费| 成人免费乱码大片A毛片| 亚洲AV无码成人精品区在线观看 | 国产成人黄色小说| 免费成人av电影| 成人国产午夜在线视频| 国产成人啪精品视频免费网| 91成人免费观看在线观看| 国产精品成人四虎免费视频| 欧美成人香蕉网在线观看| 国产精品成人久久久久久久| 成人综合伊人五月婷久久| 国产69久久精品成人看| 成人午夜精品无码区久久| 久久精品成人一区二区三区| 国产成人精品亚洲| 成人18在线观看| 成人毛片免费观看视频大全| a毛片成人免费全部播放| 免费在线成人网| 国产成人做受免费视频| 成人午夜福利视频| 欧美成人免费一区在线播放| 一级成人a做片免费| 亚洲国产成人久久综合碰碰动漫3d | 国产成人久久精品| 国产成人免费全部网站| 国产成人三级经典中文| 国产成人精品一区二区三区免费| 成人毛片在线播放| 国产欧美日韩成人| 亚洲欧美成人中文日韩电影|